Accuracy ± (0.3% of span + 1digit)
Ramp/Sork Temperature Controller
48mm x 96mm size REX-P48
96mm x 96mm size REX-P96

REX-P48 Ramp/Sork Temperature Controller




A catalog download is here.

P4896_01E.pdf (75.8KB)
(REX-P48/96)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Storage program pattern Max. 2 patterns
8 segments per pattern
(Max. 16 segments when linking 2 patterns of 8 segments each.)
Input Thermocouple, RTD
Sampling time 0.5 sec.
Measuring accuracy ±(0.3% of spsn + 1 digit)
Out of an accuracy guarantee range Thermocouple B : Between 0 and 400°C
Cold junction temperature compensation error ±1.5°C (between 0 to 50°C)
Control method PID control ( with autotuning )
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control ( with autotuning )
Control output type Relay contact output
Voltage pulse output
DC current output
Communications Not supplied
External Dimensions 48 x 96 x 100mm (W x H x D)
Standard function Programmable ramp/sork control
Optional function Level PID control (4 level)
Alarm function : Max. 2 points (Temprature alarm)
Pattern end output : 1 point
Time signal output : 1 point
External contact input : 4 points
(RESET, RUN, HOLD, STEP)
Retransmission output : 1 point
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-P96 Ramp/Sork Temperature Controller

REX-P96


A catalog download is here.

P4896_01E.pdf (75.8KB)
(REX-P48/96)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Storage program pattern Max. 2 patterns
8 segments per pattern
(Max. 16 segments when linking 2 patterns of 8 segments each.)
Input Thermocouple, RTD
Sampling time 0.5 sec.
Measuring accuracy ±(0.3% of spsn + 1 digit)
Out of an accuracy guarantee range Thermocouple B : Between 0 and 400°C
Cold junction temperature compensation error ±1.5°C (between 0 to 50°C)
Control method PID control ( with autotuning )
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control ( with autotuning )
Control output type Relay contact output
Voltage pulse output
DC current output
Communications Not supplied
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Programmable ramp/sork control
Optional function Level PID control (4 level)
Alarm function : Max. 2 points (Temprature alarm)
Pattern end output : 1 point
Time signal output : 1 point
External contact input : 4 points
(RESET, RUN, HOLD, STEP)
Retransmission output : 1 point