96mm x 96mm size
Products Typical functions
CB900 Standard temperature controller Communication, Large-size LED display
CB903 Standard temperature controller Analog retransmission output
REX-D900 Standard temperature controller Universal input and output, Advanced fuzzy logic
REX-F900 High accuracy temperature controller Many functions, High accuracy
FB900 High accuracy temperature controller Many functions, High accuracy, 60mm depth
HA900 High speed sampling controller Fast-sampling for 0.025 sec. , 2 channel control
REX-F9000 High resolution temperature controller High resolution 0.001°C, 2 channel control
REX-P96 Ramp/Soak temperature controller Program (two patterns)
REX-P250 Ramp/Soak temperature controller 16 patterns x 16 segments, Touch panel operation type
REX-P300 Ramp/Soak temperature controller 16 patterns x 16 segments, Universal input
MA900 Multi-loop temperature controller 4 channel control, Multi-memory area : 8 areas
MA901 Multi-loop temperature controller 8 channel control, Multi-memory area : 8 areas

CB900 Temperature Controller

CB900


A catalog download is here.

CB_05E.pdf (227KB)
(CB series)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage, DC current
* For DC current input, connect a 250W resister (sold separately) to the input terminals.
Sampling time 0.5 sec.
Measuring accuracy Thermocouple
±(0.3% of reading + 1 digit) or ±2°C (4°F) whichever is larger

RTD
±(0.3% of reading + 1 digit) or ±0.8°C (1.6°F) whichever is larger

DC voltage and DC current
±(0.3% of span + 1 digit)
Out of an accuracy guarantee range Thermocouple R, S, B : 0 to 399°C
Control method PID control ( with autotuning and self-tuning function )
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control (with autotuning)
Control output type Relay contact output
Voltage pulse output
DC current output : 4 to 20mA
Triac trigger output
Triac output
Communications RS-485
External Dimensions 96 x 96 x 100mm (W x H x D)
Standard function RUN/STOP switching
Optional function Alarm function : Up to 2 points (Temperature alarm, Heater break alarm, Loop break alarm)
Dustproof and waterproof protection : IP65
Go to "Quick Reference Guide" Index Page.
Go to Page Top

CB903 Temperature Controller

CB903


A catalog download is here.

CB3_03E.pdf (191KB)
(CB3 series)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage, DC current
* For DC current input, connect a 250W resister (sold separately) to the input terminals.
Sampling time 0.5 sec.
Measuring accuracy Thermocouple
±(0.3% of reading + 1 digit) or ±2°C (4°F) whichever is larger

Thermocouple T, U
-199.9 to -100.0 °C within ±3°C (6°F)

RTD
±(0.3% of reading + 1 digit) or ±0.8°C (1.6°F) whichever is larger

DC voltage and DC current
±(0.3% of span + 1 digit)
Out of an accuracy guarantee range Thermocouple R, S, B : 0 to 399°C
Control method PID control (with autotuning and self-tuning function)
* ON/OFF, P, PI and PD control are also selectable.
Control output type Relay contact output
Voltage pulse output
DC current output : 4 to 20mA
Triac trigger output
Triac output
Communications Not supplied
External Dimensions 96 x 96 x 100mm (W x H x D)
Standard function RUN/STOP switching
Optional function Alarm function : Up to 2 points (Temperature alarm, Heater break alarm, Loop break alarm)
Auxiliary output
Analog output
Contact input (DI)
Dustproof and waterproof protection : IP65
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-D900 Temperature Controller




A catalog download is here.

D_01E.pdf (79.6KB)
(D series)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Universal input
Thermocouple, RTD, DC voltage, DC current
* For DC current input, connect a 250W resister (sold separately) to the input terminals.
Sampling time 0.5 sec.
Measuring accuracy ±(0.3% of spsn + 1 digit)
Out of an accuracy guarantee range Thermocouple B : Less than 400°C
Cold junction temperature compensation error Within ±1.5°C ( between 0 and 50°C )
Control method PID control (with autotuning and self-tuning function)
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control (with autotuning and self-tuning function)
Control output type Universal output (OUT1)
Relay contact output
Voltage pulse output
DC current output
DC voltage output
Communications RS-485
RS-422A
External Dimensions 96 x 96 x 100mm (W x H x D)
Standard function Alarm function : Up to 2 points (Temperature alarm, Loop break alarm)
Optional function Heater break alarm (Single-phase, Three-phase)
Contact input
Analog output
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-F900 Process / Temperature Controller




A catalog download is here.

F_01E.pdf (137KB)
(F series)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage, DC current
Sampling time 0.25 sec.
Measuring accuracy ±(0.1% of spsn + 1 digit)
Out of an accuracy guarantee range Thermocouple B : Between 0 and 400°C
Cold junction temperature compensation error Within ±1.0°C (between 0 and 50°C)
Accuracy is not guarantee less than input value -100°C.
Control method ON/OFF control
Brilliant PID control (PI control is selectable.)
(with enhanced autotuning)
Heat/cool brilliant PID control
(with enhanced autotuning)
Position proportioning control
Control output type Relay contact output
Voltage pulse output
DC current output
DC voltage output
Communications RS-232C
RS-422A
RS-485
External Dimensions 96 x 96 x 70mm (W x H x D)
Standard function
Memory Area : 8 areas (REX-F700/900)
2 areas (REX-F400)
*REX-F400 of 8 areas type if Z-163 is specified.
Optional function Alarm function : Up to 2 points (Temperature alarm, Heater break alarm, FAIL alarm)
Analog output
Remote set value function
External contact intput : 1 point (Memory area or Mode change)
Go to "Quick Reference Guide" Index Page.
Go to Page Top

FB900 Process / Temperature Controller

FB900 temperature controller product photo


A catalog download is here.

FB_03E.pdf (1.01MB)
(FB series)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage, DC current
Sampling time 0.1 sec.
0.05 sec. / 0.25 sec. is selectable.
Measuring accuracy Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)

Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)

Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±(1.4°C + 1 digit)
More than 1000°C : ±(0.1% of reading + 1 digit)

RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)

DC voltage and DC current
±(0.1% of span)
Cold junction temperature compensation error ±1.0°C (between 5 to 40°C)
With in ±1.5°C
(between -10 to +5°C , between 40 to 50°C)
Control method Brilliant II PID control
(with autotuning and startup tuning)
Brilliant II PID control Heat/Cool type
(with autotuning)
Position proportioning control l without feedback resistance (with autotuning)
Control output type Relay contact output
Voltage pulse output
DC current output
DC voltage output
SSR (Triac) output
Open collector output (Sink type)
Communications Communication 1
RS-232C
RS-422A
RS-485
* MODBUS

Communication 2 (Inter-controller communication)
RS-485
External Dimensions 96 x 96 x 60mm (W x H x D)
Standard function Memory area : 8 areas
Digital input : 3 points (Mode selection)
Remote setpoint input
Waterproof/Dustproof : NEMA4X, IP66
(Waterproof/Dustproof protection only effective from the front in panel mounted installation.)
Optional function Ivent (alarm) output : Max. 4 points
Digital input : 4 points (Memory area selection + Area set)
Heater break alarm
Analog retransmission output : 1 point
Position resistance input
Power feed forward function
Go to "Quick Reference Guide" Index Page.
Go to Page Top

HA900 Process / Temperature Controller

HA900


A catalog download is here.

HA_01E.pdf(533KB)
(HA series)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage, DC current
* Number of inputs : 2 points
Sampling time 0.25 sec.
Measuring accuracy Thermocouple : K, J, T, E, PLII
Less than -100°C : ±1.0°C
-100 to 500°C : ±0.5°C
More than 500°C : ±(0.1% of reading + 1 digit)

Thermocouple : N, S, R, W5Re/W26Re
Less than -100°C : ±2.0°C
-100 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)

Thermocouple : B
Less than 400°C : ±70.0°C
400 to 1000°C : ±1.0°C
More than 1000°C : ±(0.1% of reading + 1 digit)

RTD
Less than 200°C : ±0.2°C
More than 200°C : ±(0.1% of reading + 1 digit)

DC voltage and DC current
±(0.1% of span + 1 digit)
Cold junction temperature compensation error ±1.0°C ( at 23°C ± 2°C )
±1.5°C ( between 0 to 50°C )
Control method Brilliant PID control (with enhanced autotuning)
Position proportioning control
Control output type Relay contact output
Voltage pulse output
DC current output
DC voltage output
Communications Number of communications : 2 points
RS-232C
RS-422A
RS-485
* MODBUS, DeviceNet, Profibus supported.
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Memory area : 16 areas
Cascade control ( only 2 channel type )
Optional function Ivent (alarm) output : Max. 4 points
Ivent input : 7 points
Remote set value function
Heater break alarm
Analog retransmission output : 3 points
Position feedback resistance input
(Position proportioning control)
Power feed forward function
Waterproof/Dustproof : IP65
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-F9000 Temperature Controller

REX-F9000


A catalog download is here.

F9000_01E.pdf (69.2KB)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input 4 wire system RTD ( 0.000 to 50.000°C )
* Number of inputs : 2 points
Sampling time 0.1 sec.
Measuring accuracy ±0.05°C
Control method Brilliant PID control ( with autotuning )
Control output type Voltage pulse output
DC current output
Communications RS-485
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Alarm function : Up to 3 points ( Temperature alarm, FAIL alarm )
External contact intput : 1 point ( RUN/STOP )
Optional function Analog retransmission output
Power feed forward function
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-P96 Ramp/Sork Temperature Controller

REX-P96


A catalog download is here.

P4896_01E.pdf (75.8KB)
(REX-P48/96)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Storage program pattern Max. 2 patterns
8 segments per pattern
(Max. 16 segments when linking 2 patterns of 8 segments each.)
Input Thermocouple, RTD
Sampling time 0.5 sec.
Measuring accuracy ±(0.3% of spsn + 1 digit)
Out of an accuracy guarantee range Thermocouple B : Between 0 and 400°C
Cold junction temperature compensation error ±1.5°C (between 0 to 50°C)
Control method PID control ( with autotuning )
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control ( with autotuning )
Control output type Relay contact output
Voltage pulse output
DC current output
Communications Not supplied
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Programmable ramp/sork control
Optional function Level PID control (4 level)
Alarm function : Max. 2 points (Temprature alarm)
Pattern end output : 1 point
Time signal output : 1 point
External contact input : 4 points
(RESET, RUN, HOLD, STEP)
Retransmission output : 1 point
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-P250 Ramp/Sork Temperature Controller

REX-P250


A catalog download is here.

P250_02E.pdf (190KB)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Storage program pattern Max. 16 patterns
16 segments per pattern
( Max. 256 segments when linking 16 patterns of 16 segments each. )
Input Thermocouple, RTD, DC voltage, DC current
Sampling time 0.5 sec.
Measuring accuracy Thermocouple :
±(0.3% of reading + 1 digit) or ±2°C

RTD
±(0.3% of reading + 1 digit) or ±0.8°C

DC voltage and DC current
±(0.2% of span + 1 digit)
Out of an accuracy guarantee range Thermocouple R, S, B : Between 0 and 400°C
Control method PID control ( with autotuning )
* ON/OFF, P, PI and PD control are also selectable.

Position proportioning control
Control output type Relay contact output
Voltage pulse output
DC current output
DC voltage output
Triac trigger output
Communications RS-232C
RS-422A
External Dimensions 96 x 96 x 150mm ( W x H x D )
Standard function Programmable ramp/sork control
Multi memory area : 8 areas
Pattern end output : 1 point ( Open collector )
Time signal output : 4 points ( Open collector )
External contact input : 9 points
( RESET, RUN, HOLD, STEP, Pattern SET )
FAIL alarm
Optional function Alarm function : Up to 2 points (Temperature alarm, Heater break alarm)
Analog retransmission output
Go to "Quick Reference Guide" Index Page.
Go to Page Top

REX-P300 Ramp/Sork Temperature Controller

REX-P300


A catalog download is here.

P300_02E.pdf (191KB)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Storage program pattern Max. 16 patterns
16 segments per pattern
( Max. 256 segments when linking 16 patterns of 16 segments each. )
Input Universal input
Thermocouple, RTD, DC voltage, DC current
Sampling time 0.1 sec.
Measuring accuracy Thermocouple
(±0.1% of reading or ±1°C) ± 1digit

RTD
(±0.1% of reading or ±0.5°C) ± 1digit

DC voltage and DC current
±(0.1% of span + 1 digit)
Out of an accuracy guarantee range Thermocouple B, PR20-40 : Less than 400°C
RTD JPt100 : More than 500°C
Cold junction temperature compensation error Within ±0.5°C ( between 0 and 50°C )
But input value does not guarantee less than -100 °C.
Control method PID control ( with autotuning )
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control ( with autotuning )

Position proportioning control without feedback resistance
Control output type Relay contact output
Voltage pulse output
DC current output
DC voltage output
Communications RS-232C
RS-422A
RS-485
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Programmable ramp/sork control
Level PID control (4 level)
Pattern end output : 1 point ( Open collector )
Time signal output : 4 points ( Open collector )
External contact input : 4 points
( RESET, RUN, HOLD, STEP )
Alarm function : Max. 2 points
Optional function Time signal output : In the case of 8 points.
Auxiliary output : Max. 3 points
External contact input : 5 points ( Pattern set )
Analog retransmission output
Go to "Quick Reference Guide" Index Page.
Go to Page Top

MA900 Multi-loop temperature controller

MA900


A catalog download is here.

MA900_03E.pdf (191KB)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage
Number of channels 4 channels
Sampling time 0.5 sec.
Measuring accuracy Thermocouple
±(0.3% of reading + 1 digit) or ±2°C (4°F) whichever is larger

RTD
±(0.3% of reading + 1 digit) or ±0.8°C (1.6°F) whichever is larger

DC voltage
±(0.3% of span + 1 digit)
Out of an accuracy guarantee range Thermocouple R, S, B : Less than 399°C
Thermocouple K, J, T, U : Less than -100°C
Control method PID control ( with autotuning and self-tuning function )
* ON/OFF, P, PI and PD control are also selectable.

Heat/cool PID control ( with autotuning )
Control output type Relay contact output
Voltage pulse output
DC current output : 4 to 20mA
Triac output
Communications RS-232C
RS-422A
RS-485
* MODBUS supported.
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Memory area : 8 areas
Optional function Alarm function : Up to 3 points ( Temperature alarm, Heater break alarm, Loop break alarm )
External contact intput : 5 point ( RUN, STOP, Memory area change )
Go to "Quick Reference Guide" Index Page.
Go to Page Top

MA901 Multi-loop temperature controller

MA901

A catalog download is here.

MA901_03E.pdf (154KB)


Specification files are in Adobe's Acrobat PDF file (version 4.0) format.
Acrobat Reader is required.
Input Thermocouple, RTD, DC voltage
Number of channels 4 channels
Sampling time 1 sec.
Measuring accuracy Thermocouple
±(0.3% of reading + 1 digit) or ±2°C (4°F) whichever is larger

RTD
±(0.3% of reading + 1 digit) or ±0.8°C (1.6°F) whichever is larger

DC voltage
±(0.3% of span + 1 digit)
Out of an accuracy guarantee range Thermocouple R, S, B : Less than 399°C
Thermocouple K, J, T, U : Less than -100°C
Control method PID control ( with autotuning and self-tuning function )
* ON/OFF, P, PI and PD control are also selectable.
Control output type Relay contact output
Voltage pulse output
DC current output : 4 to 20mA
Triac output
Communications RS-232C
RS-422A
RS-485
* MODBUS supported.
External Dimensions 96 x 96 x 100mm ( W x H x D )
Standard function Memory area : 8 areas
Optional function Alarm function : Up to 3 points ( Temperature alarm, Heater break alarm, Loop break alarm )
External contact intput : 5 point ( RUN, STOP, Memory area change )
Go to "Quick Reference Guide" Index Page.
Go to page top
߂ RKC INSTRUMENT INC.