MCU-based Heater Break Alarm (for single/three phase power controllers), DIN-rail mounting type
HBA-T120 / HBA-T130
- Heater break alarm for single phase or three phase power control
- Available for phase control, zero-cross control, relay contact, and SSR drive
- Automatic setting of the load current
- Supported CT: MCTL-6-P-N (load current up to 30A), MCTL-12-S56-10L-N (load current up to 100A)
※Two CTs are used for three phase control.
- Temperature
- Download
- Main features
- Main specification
- External dimensions
- Models
Main features
HBA-T120 (for a single phase power control system)
Automatic setting of load current using a built-in MCU. Used for phase control and zero cross control by a power controller.
Supported CT: MCTL-6-P-N (load current up to 30A), MCTL-12-S56-10L-N (load current up to 100A)
※Available for relay contact or SSR drive control systems
HBA-T130 (for a three phase power control system)
Automatic setting of load current using a built-in MCU. Used for phase control and zero cross control applications by a three phase power controller.
Supported CT: MCTL-6-P-N (load current up to 30A), MCTL-12-S56-10L-N (load current up to 100A)
※Two CTs are used for three phase control.
※Available for relay contact or SSR drive control systems
Main specification
HBA-T120 (for a single phase power control system)
- Input type:
HBA-T120□-5 MCTL-6-P-N
HBA-T120□-30 MCTL-6-P-N
HBA-T120□-100 MCTL-12-S56-10L-N
- Detectable load current:
HBA-T120□-5 1 to 5A (Rating: 5A)
HBA-T120□-30 6 to 30A (Rating: 30A)
HBA-T120□-100 20 to 100A (Rating: 100A)
- Settable range: 0 to 30% of the rated value of the device set in rate of current decrease (0 to 15%×2 of alarm set value)
- Accuracy of load setting: within ±3% of load set value
- Accuracy of alarm setting: within ±3% of load set value
※Accuracy is not guaranteed when the load voltage is 30% or less of the rating.
HBA-T130 (for a three phase power control system)
- Input type:
HBA-T130□-5 MCTL-6-P-N
HBA-T130□-30 MCTL-6-P-N
HBA-T130□-100 MCTL-12-S56-10L-N
- Detectable load current:
HBA-T130□-5 1 to 5A (Rating: 5A)
HBA-T130□-30 6 to 30A (Rating: 30A)
HBA-T130□-100 20 to 100A (Rating: 100A)
- Settable range: 0 to 30% of the rated value of the device set in rate of current decrease (0 to 15%×2 of alarm set value)
- Accuracy of load setting: within ±3% of rated capacity of alarm unit
- Accuracy of alarm setting: within ±3% of rated capacity of alarm unit
※Accuracy is not guaranteed when the load voltage is 30% or less of the rating.
<Common specification>
- Alarm output: 1 point, Relay contact, 1a contact
- Supply voltage: 100 to 220V, 50/60Hz
- Power consumption: 1.2VA or less
- Operating ambient temperature: 0 to 50°C